Hi Bill,
Consider using the spider as 1/2 the circuit. Your cat5 cable wire
should work for the other half (or even both legs of the circuit), since
it is less than 1/10 ohm per foot. You could run your #18 from the
controller to the spider assy, then use the short length of small wire.
I made the center piece of my spider out of insulating material, and use
two legs of the spider to carry the juice to the secondary....works good.
So, a quick "yay" to using your tiny wire the length of the spider arms,
then use heavier wire from the top of the scope to the controller.
Chuck in N. Florida
Bill wrote:
> I don't know the numbers involved, or what to do with them if I had them,
> but hopefully someone is familiar enough to give me a quick 'yay' or
> 'nay'.
> The Astrosystems secondary dew circuit, is it ok to use the small phone
> wires, like inside a CAT5 cable, to power this guy? Other than that I
> have huge 18 ga wire which I know is way overkill.
>
> This to me (the phone wires) would be ideal for running along a spider
> vane as far as least intrusion into the light path. As long as it can
> handle the wattage, does anyone know?
>
> Thanks,
> Bill
>
>
>
> ____________________________________________________________________________________
> Looking for a deal? Find great prices on flights and hotels with Yahoo! FareChase.
> http://farechase.yahoo.com/
> _______________________________________________
> ATM mailing list http://www.atmlist.net/
>
>
>
--
--------------------
Chuck Broward
GhastlySky Observatory
"If you think you are too small to make a difference,
try sleeping in a closed room with a mosquito."
_______________________________________________
ATM mailing list http://www.atmlist.net/