[ATM] Foucault/interferometry comparisons



ATM and atm_free,

I put together a report that presents eight examples I have collected of cases
where Foucault and interferometry don't agree.  The heart of the report is eight
graphs where I overlay surface profiles derived from interferometry and Foucault
so they can be compared directly.  The report is here:

    http://www.visi.com/~mkoehler/fi_examples/fi_examples.html

I intend this to be a working paper, and will add more examples to it as I find
them.  My main point is that when Foucault and interferometry disagree (and they
don't always), it seems that Foucault sees the mirror over-corrected with
respect to interferometry.  I would be very interested in either more examples
of the same, or examples that contradict this pattern.

Sorry for the double posting, but this topic is currently being discussed on
both groups.

-- Steve Koehler
   steve_koehler@securecomputing.com


_______________________________________________
ATM mailing list http://www.atmlist.net/