Re: [ATM] Figure Stroke 8 inch
At 2004-03-13 11:25 -0800, tomfred@flash.net wrote:
>I am figuring an 8 inch f6 very close to parabola 1/4 wave.
>Here are the numbers moving source if you care to run them.
>
>zone readding 1 readding 2 readding 3 readding 4
>1 0.000 0.000 0.000 0.000
>...
I had to guess at your zone radii to get the following Sixtests input file:
-----------------------
tomfred
8
Foucault
0
y X
1.21 0
2.43 0.037
3.15 0.053
3.73 0.067
*
0 0
0.006
48
INCH
------------------------
Sixtests says you have work ahead - surface RMS 289 nm (want 20 nm),
surface PV 1250 nm. Anyway, the main number was the best-fit conic b =
-.480, undercorrected; probably the safest thing is to do one of Texereau's
parabolizing strokes on p. 97. One of the "A classic methods" should work
on an 8"f/6.
-- Jim Burrows
-- mailto://burrjaw@earthlink.net
-- http://home.earthlink.net/~burrjaw
-- Seattle N47.4723 W122.3662 (WGS84)
_______________________________________________