[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: [ATM] wire spiders



Oh: correction:
I mentioned 8 degrees: that is the angle between the wire and upperring.
The angle between the wires relative to each other is about 16 degrees.

Harrro TReur

> -----Oorspronkelijk bericht-----
> Van: Treur, Harro [mailto:harro.treur@waternet.nl] 
> Verzonden: woensdag 28 juni 2006 12:53
> Aan: 'Jan van Gastel'; 'atm@atmlist.net'
> Onderwerp: Re: [ATM] wire spiders
> 
> 
> Hello Jan,
> 
> In my  12,5 inch, the wires have a small angle. 
> In fact, it amazes me how small the angle can be without the 
> spider moving away or vibrating.
> 
> In my first design, it was possible to change the vertical 
> distance between the wires. This way I was able to place the 
> secondary on the desired position. I experimented with 
> several angles. I found that an angle of only 8 degrees is 
> sufficient. My secondary is quite large (63 mm) and therefore 
> not very lightweight. But the tension in the wires must be 
> quite high. 
> 
> I realise that in a 20 inch, the weight of the secondary is 
> somewhat more and that the wires are longer (The length of my 
> wires is about 150mm. In a 20inch this will be 220mm). But I 
> am convinced that an angles of 35 degrees is way too much. I 
> think that 15 degrees is more than enough for your 20inch-telescope.
> 
> If you hesitate, I advise that you experiment with different angles.
> 
> Good luck
> Harro Treur
> 
> PS: Jan, how is the grinding going?? 
> 
> 
> 
> > -----Oorspronkelijk bericht-----
> > Van: Jan van Gastel [mailto:jhm.vangastel@wanadoo.nl]
> > Verzonden: woensdag 28 juni 2006 9:33
> > Aan: atm@atmlist.net
> > Onderwerp: [ATM] wire spiders
> > 
> > 
> > I have been searching for information on the internet about 
> the angle 
> > between the wires of a wire spider. I found some postings, 
> including 
> > one of Mel Bartels and one of Nils Olof Carlin, telling 
> there has to 
> > be 'some' angle, but not how large that should be. Nils 
> Olof, pointing 
> > to bike wheels suggests, if I understand him well, that the angle 
> > doesn't need to be large.
> > 
> > I want to use Mel's crossing system on the trilateral 20 
> incher I am 
> > building at the moment. When I make the central hub and the 
> side bars 
> > 150 mm
> > (6") long, the angle between wires at the crossing point will
> > be about 35 degrees, the angle between hub (or side bars) and 
> > wires about 27 degrees.
> > 
> > Is this the way to go, or should the angle still be larger? 
> Or is this 
> > overkill and is a smaller angle also OK?
> > 
> > 
> > Jan
> > http://home.wanadoo.nl/jhm.vangastel/Astronomy/
> > 
> > _______________________________________________
> > ATM mailing list http://www.atmlist.net/
> > 
> 
> Waterleidingbedrijf Amsterdam is per 1 januari 2006 gefuseerd 
> met DWR tot Waternet. De adressen en telefoonnummers blijven 
> voorlopig gelijk. De emailadressen zijn al 
> wel gewijzigd maar de oude emailadressen blijven voorlopig bestaan.
> 
> _________________________________________________________________
> 
> De informatie verzonden in dit e-mailbericht is vertrouwelijk 
> en uitsluitend bestemd voor de geadresseerde. Openbaarmaking, 
> vermenigvuldiging, verspreiding en/of verstrekking van deze 
> informatie aan derden is, behoudens voorafgaande 
> schriftelijke toestemming van Waternet, niet toegestaan. 
> Waternet staat niet in voor de juiste en volledige 
> overbrenging van de inhoud van een verzonden e-mailbericht, 
> noch voor tijdige ontvangst daarvan.
> 
> _________________________________________________________________
> _______________________________________________
> ATM mailing list http://www.atmlist.net/
> 

Waterleidingbedrijf Amsterdam is per 1 januari 2006 gefuseerd met DWR tot Waternet.
De adressen en telefoonnummers blijven voorlopig gelijk. De emailadressen zijn al 
wel gewijzigd maar de oude emailadressen blijven voorlopig bestaan.

_________________________________________________________________

De informatie verzonden in dit e-mailbericht is vertrouwelijk en uitsluitend bestemd voor de geadresseerde. Openbaarmaking, vermenigvuldiging, verspreiding en/of verstrekking van deze informatie aan derden is, behoudens voorafgaande schriftelijke toestemming van Waternet, niet toegestaan. 
Waternet staat niet in voor de juiste en volledige overbrenging van de inhoud van een verzonden e-mailbericht, noch voor tijdige ontvangst daarvan.

_________________________________________________________________
_______________________________________________
ATM mailing list http://www.atmlist.net/