[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: [ATM] Finder
Richard F.L.R. Snashall wrote:
>
>
> Even then, the last doublet no longer has matching OTS
> surfaces.
With a more vignetting (40% throughput at the field
edge) and less magnification (7 mm exit pupil),
however:
Title: Ptz07-17x
48.8 mm f/6 Refractor with Erfle Eyepiece
Field: 8.2 Degrees
AFOV: 62+ Degrees
Sugg: MG LDX189 and LPX259
Sugg: MG LDX145(2) (and LPX249 in a pinch)
Surf Radius Thickness Glass Diameter
STO Infinity -2.303521 48.8
2 130.38 8 N-BK7 50.8
3 -130.38 0.341 50.8
4 -130.38 3 N-F2 50.8
5 Infinity 184.085 50.8
6 91.814 6.6 N-BK7 50.8
7 Infinity 30.266 50.8
8 -91.814 3 N-BAK2 39.2
9 130.38 54.97938 39.2
10 Infinity 21.38537 42.23387
11 77.038 11.5 N-BK7 50.8
12 -77.038 3 N-SF1 50.8
13 77.038 11.5 N-BK7 50.8
14 -77.038 0.1 50.8
15 Infinity 7.316 N-BK7 50.8
16 -77.038 0.1 50.8
17 77.038 11.5 N-LAF34 50.8
18 -77.038 3 N-SF5 50.8
19 Infinity 33.42887 50.8
IMA Infinity 9.19121
That middle lens in the eyepiece is designed so the
spacers have the same length as if the MG lens were
used. Even then, the external spacing (21.38537 and
33.42887) will change with the substitution.
_______________________________________________
ATM mailing list http://www.atmlist.net/