Hi,
I am redesigning my mirror cell and ran my numbers through PLOP.
My Pyrex mirror has an OD of 12.6" and an average thickness of 1.9". If
I run a 4 point cell I get an error of 2.01375e-06 mm RMS and a support
ring at .508337 X radius. This is approximately 1/2 the max error of
4.20e-06 mm as per the web page user manual. As a reality check, does
this sound reasonable or have I missed something?
Looking forward to any comments, soon to be cutting wood and metal.