Hi Richard,

Thanks for the software, however I think you may miss diameter of the lenses 
and the thickness between & of 2 correctors.
I use OSLO (a professional optical software) to examinate the result 
calculated by your software. For below result it doesn't come to a good spot 
diagram.
-----------LH calculator result----------
Glass: Schott BK7
Focal lenth:1250mm
Separation:1070mm
Result: R1=2016, R2=-5539, R3=-2016, R4=5539
-----------------------------------------------

-----------OSLO optimize result-------------
Glass: Schott BK7
Focal lenth:1250mm
Diameter=250mm
Separation:1070mm
Result: R1=2029, R2=-5341, R3=-2029, R4=5341
Thickness: lens1=10, corrector interval=3, lens2=6
-----------------------------------------------

Wish this will be helpful to your software.

Best Regards,
Ukyo Chen



>From: Richard <cnc@cncservo.co.uk>
>Reply-To: Richard <cnc@cncservo.co.uk>
>To: ATM List <atm@atmlist.net>
>Subject: Re: [ATM] Lurie Houghton Calculator
>Date: Tue, 23 Aug 2005 00:53:23 +0100
>
>Hi,
>
>R> 
>http://www.atmlist.net/contrib/cnc-at-cncservo-dot-co-dot-uk/LH1.1.0.40.zip
>
>has been replaced by :
>
>http://www.atmlist.net/contrib/cnc-at-cncservo-dot-co-dot-uk/LH1.1.0.42.zip
>
>due to a small bugette :)
>
>--
>