[ATM] Foucault Test Analysis 2.0B



Hello,

After over a year I have provided a new version of my mirror evaluation program Foucault Test Analysis 2.0B.
You can download it from:

http://www.foucault-test-analysis.de/page_eng.htm

The main difference compared with 2.0A is that the new version offers the

- lateral wire test and
- caustic test 

now.

Further changes are:

* Within the window "mirror setup" you can decide wether the measurement-values becomes smaller or larger when moving the test apperatus sidewards or towards the mirror. With this feature the manual turn over of the measurements is obsolete.
* If you keyed in multiple series of measurements for one reading you can calculate the mirror-results for each single measurement now.
* Regarding the shadowgram-simulation the new tests (caustic-test, lateral wire test) are simulated, too. The single measurement-points can be found by pressing the "Find Measure Point"-button.
* Within the settings-window you can choose between "Linear Splines" and "Cubic Splines" as Interpolation-method. With "Linear Splines" you get nearly the same results as with FigureXP for paraboloidal mirrors (conic constant = -1).

Suggestions for further development and criticism are welcome.


Greetings,

Andreas Reifke