[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: [APML] Arizona Pix
Hi,
The vacuum used was less than 50 microns, I run the pump for 30 minutes and
it usually pulls about 200 microns. The rest is correct.
Jim
----- Original Message -----
From: "Matt BenDaniel" <matt@exceloncorp.com>
To: <astro-photo@seds.org>
Sent: Monday, May 28, 2001 9:25 AM
Subject: RE: [APML] Arizona Pix
> At 11:15 AM 5/28/2001, Jeff Ball wrote:
> >Hey Matt,
> >Great stuff. I love the hypered PPF look of M8 and M20.
>
> Jeff,
>
> Thanks.
>
> >Did you hyper your
> >PPF on the reel or slightly unwound inside the hyper chamber or other?
>
> The PPF was hypered in Jim Janusz's 1200 chamber. 50 micron vacuum. 12
hours at 38C, 15 PSI.
> It was hypered on the spool, tightly wound.
> No camera purging was necessary (for hypered 120 color film) in Arizona's
dry atmosphere.
>
> --
> Matt BenDaniel
> http://starmatt.com
>
>
> -- APML Archives at <http://astro.umsystem.edu/apml/> ---
> Unsubscribe at <majordomo@seds.org>
-- APML Archives at <http://astro.umsystem.edu/apml/> ---
Unsubscribe at <majordomo@seds.org>