"Shekhar Borde" <shekhar@prodigy.net> wrote:
>
>Do any of the Vixen scopes take OAGs or filters?
I think they are designed for guidescopes.. my R200SS is very stout, absolutely
no problems using a quide scope.
>
>I have the R200SS and I like it for the most part. One minor annoyance
>is that it will not take an OAG (understandable at f/4).
I once modified mine by adding a 2" spacer to the mirror cell, this allowed the
use of a Lumicon newt easy guider and its coma corrector.. worked well but when
I changed my guidescope then I stopped using the off-axis guider and went back
to the guidescope..
> A major annoyance
>is that it will not take a filter. There is no easy way to insert a filter in the
>light path. You have to hack something together -- like gluing in the filter
>into the T-ring or devise something like a gel filter holder at the bottom of
>the focuser tube (as Wil Milan did with his Epsilon).
Luckily I can screw a 48mm filter into the end of the coma corrector.. but that
may be possible just with my coma corrector.. you can always glue in a step-down
ring somewhere in the light path.
>
>BTW, I think that Orion has stopped selling (or at least listing) this scope.
>I wonder why?
I just got a Vixen catalog, there is lots of stuff that Orion never showed in
their catalog. They even have a flat field 4" apo that will take medium format,
20um stars over a 90mm circle.
Herm
Astropics http://home.att.net/~hermperez